Telecom Access Copper Pair Cables

Image

We offer air cables designed for XDSL and POTS transmission in telecom access network applications.

Our product range covers unscreened, screened, single or multi pair, wire size 0.4-0.7 mm, halogen-free flame retardant for indoor, and  weather protected outdoor versions for duct and aerial installation.

Access Pair Cables


EUALEV
Intended for outdoor use in distribution networks. The cable is polyethylene insulated, pair twisted into units, jelly filled, screened by an aluminum tape and jacketed with polyethylene. Suitable for underground installations in ducts or direct buried.

  • Halogen-free design
  • Complies with Swedish standard SS 424 16 22 and TeliaSonera A 952 1694
  • Cable size 5 - 300 pair
  • Impedance 120 ohm
  • Conductor 0.5 mm, 24 AWG and 0.7 mm
  • Excellent protection for water penetration by the moisture barrier of aluminum tape and jelly filling
  • Outdoor installations
 

ECALEV
Intended for outdoor use in distribution networks. The cable is polyethylene insulated, pair twisted into units, dry water-block, screened by an aluminum tape and jacketed with polyethylene. Suitable for underground installations in ducts or direct buried.
  • Suitable for XDSL application
  • Impedance 120 ohm
  • Halogen-free
  • Dry, water-block protection for water penetration with moisture barrier of aluminum tape bounded to PE jacket, secure installations in wet conditions
  • Cable sizes 5-100 pair with conductor sizes 0.5 as standard
  • Complies with TeliaSonera A 952 1680  based upon Swedish standard SS 424 16 22


ELALE
Intended for outdoor use in access networks. The cable is polyethylene insulated, pair twisted into units, screened by an aluminum tape and jacketed with polyethylene. Suitable for underground installations in ducts or direct buried in pressurized network and maintenance of paper insulated cables.
  • Halogen-free design
  • Complies with TeliaSonera A 952 1690
  • Cable size 10-100 pair
  • Conductor 0.5 mm
  • Excellent protection for water penetration by the moisture barrier of aluminum tape
  • Outdoor installations


ELLCE
Intended for outdoor use in distribution networks. Polyethylene insulated, pair twisted into units and jacketed with polyethylene including an suspension strand of zinc coated steel wires. Suitable for overhead installations on poles.
  • Figure-8 design with standardized suspension web for easier installation
  • Robust design with solid insulation of Polyethylene
  • Cable sizes 5 - 100 pair with conductor sizes 0.5 and 0.7mm as standard
  • Complies with Swedish standard SS 424 16 62 and TeliaSonera A 099 0222


ELLY
Intended for outdoor use as a subscriber cable in distribution networks. The cable is polyethylene insulated, twisted into a star quad and jacketed with polyethylene. Suitable for buried installations
  • Compact and durable design
  • Cable size 2 pair with conductor size 0.6 mm as standard
  • Complies with Swedish standard SS 424 16 60 and TeliaSonera A 952 1689


ELLC
Intended for outdoor use as an aerial subscriber cable in distribution networks. The cable is polyethylene insulated, twisted into a star quad and jacketed with polyethylene including an suspension strand of zinc coated steel wires. Suitable for overhead installations on poles.
  • Figure-8 design with standardized suspension web for easier installation.
  • Robust design with solid insulation of Polyethylene
  • Cable size 2 pairs with conductor size 0.6 mm as standard
  • Complies with Swedish standard SS 424 16 61 and TeliaSonera A 099 0223


ELQXBE (ELLXEB)
Intended for indoor use in telecom systems. The cable is polyethylene insulated, pair twisted into units or twisted into a star quad for 2 pair cable. Jacketed with a halogen-free thermoplastic compound.
  • Halogen-free design
  • Un-screened
  • Conductor 0.5 mm 24 AWG
  • Cable sizes 2-100 pair
  • Complies with SS 424 16 92
  • Flame-retardant IEC 60332-1-2, SS 424 1475 F2


ELAQBEU
Intended for indoor use in telecom systems. The cable is polyethylene insulated, pair twisted into units, screened by an aluminum foil and jacketed with a halogen-free thermoplastic compound. Ideally suited for XDSL applications and E1 transmission.
  • Halogen-free design
  • Screened by AL-foil
  • Conductor 0.5 mm 24 AWG
  • Cable sizes 10-100 pair
  • Impedance 120 ohm
  • Complies with SS 424 16 93, TeliaSonera A 952 1676
  • Flame-retardant IEC 60332-3-24


ELAQBY
Intended for indoor and outdoor use in telecommunication, data and alarm systems. The cable is polyethylene insulated, pair twisted into units, screened by an aluminum foil and jacketed with a halogen-free thermoplastic compound.
  • Screened by an aluminum foil
  • Halogen-free
  • Flame-retardant IEC 60332-1-2 , SS 424 1475 F2
  • Robust design with insulation of solid polyethylene
  • Cable sizes 2-100 pair with conductor size 0.6 mm
  • Complies with SS 424 16 52


ELQYB
Intended for indoor and outdoor non-buried installations as subscriber cable in distribution networks. The cable is polyethylene insulated, twisted into a star quad and jacketed with a halogen-free thermoplastic compound.
  • Halogen-free design
  • Unscreened  
  • Conductor 0.6 mm
  • Cable size 2 pair
  • Indoor and outdoor installations
  • Complies with SS 424 16 53
  • Flame-retardant IEC 60 332-1-2


EKU
Intended for indoor use as a subscriber cable in distribution network for telecom and signaling systems. Twin copper conductors laid in parallel and jacketed with a flame-retardant PVC compound.
  • Compact and durable design.
  • Cable size 1 pair with conductor size 0.7 mm as standard.
  • The web between conductors enables fast and simple installation by nailing
  • Complies with Swedish standard SS 424 16 02
  • Flame-retardant IEC 60332-1-2
  • RoHS compliant


EQQXBU (ELLXB)
Intended for indoor use in telecommunication, data and alarm systems. The cable is insulated with a flame retardant halogen-free compound, pair twisted into units and jacketed with a halogen-free, flame-retardant thermoplastic compound.
  • Halogen-free
  • Flame-retardant IEC 60332-3-24, SS 424 1475 F4C
  • Cable sizes 2-100 pair with conductor size 0.5 mm
  • Complies with SS 424 16 90