Data Cables for Interconnect and Structured Networks

Structured networks rely on high quality cables with enhanced transmission properties and robust designs to ensure a trouble free data network for the future of multimedia applications.

Our portfolio includes all the standard types as CAT5, CAT6 and CAT7 screened, unscreened halogen-free and UL listed. Optimized versions down-sized to AWG 26 - 30 used in dense application intermediate links within switching nodes, data center and radio access nodes. Weather-protected designs for outdoor and direct-buried applications. 

Data Cables


TFL 301 5010 FMQXB/100, Cat 5e, U/UTP, 26 AWG, Patch
Flexible U/UTP patch cable for interconnecting data and telecom equipment. Polypropylene insulated stranded wire, pair twisted and jacketed with a halogen-free compound. Intended for indoor use.

  • Halogen-free design
  • Screened by AL-foil and braid
  • Conductor, tin plated stranded wire, 26 AWG
  • UL listed CMR


TEL 301 6010 ECAFQBU/100, Cat 5e SF/UTP, 24 AWG
Designed for interconnecting data bus links within telecom and datacom applications. Foamed PE insulation, pair twisted, screened by an AL-foil and braid jacketed with a halogen-free, flame-retardant compound. Extending EMC properties of standard CAT5e cable.
  • Halogen-free design
  • Screened by AL-foil and braid
  • Conductor 0.5 mm, 24 AWG
  • UL listed CMR


TFL 301 6010 FLAFQBU/100, Cat 5e SF/UTP, 26 AWG, Patch
Designed for interconnecting data bus patch links with in telecom and datacom applications. Robust design with solid PE insulation on a stranded tinned cu wire, pair twisted, screened by an AL-foil and braid jacketed with a halogen-free, flame-retardant compound.
  • Halogen-free design
  • Screened by AL-foil and braid
  • Conductor 0.14 mm2, 26 AWG
  • UL listed CMR


TEL 301 8010 ECEFQBU/100, Cat 6 S/FTP, 23 AWG
S/FTP Cat 6 design with excellent transmission properties. Ideally suited to interconnect telecom and data system in structured data networks. The cable is polyolefin insulated, pair twisted and screened by an aluminum foil. Overall screened by a tinned copper braid and jacketed with a halogen-free compound. Intended for indoor use.
  • Halogen-free design
  • Screened by AL-foil and braid
  • Cconductor 23 AWG
  • UL listed CMR


TEL 301 8011 ECEFQBU/100, Cat 6 S/FTP, 26 AWG
Optimized S/FTP Cat 6 design downsized to 26 AWG offering with reduced dimension but the same excellent transmission properties. Ideally suited to interconnect telecom and data system. The cable is polyolefin insulated, pair twisted and screened by an aluminum foil. Overall screened by a tinned copper braid and jacketed with a halogen-free compound. Intended for indoor use.
  • Halogen-free design
  • Screened by AL-foil and braid
  • Conductor  26AWG
  • UL listed CMR


TEL 301 8018 ECEFL/100, Cat 6 S/FTP, 23 AWG, Outdoor
Design with excellent transmission properties. Ideally suited to interconnect telecom and data system in outdoor structured data networks. The cable is polyolefin insulated, pair twisted and screened by an aluminum foil. Overall screened by a tinned copper braid and jacketed with Polyethylene.
  • Weather-proof for outdoor use
  • Halogen-free design
  • Screened by AL-foil and braid
  • Conductor 23 AWG
  • UL listed CMR


TEL 301 5020 EMQXBU/100, Cat 6 U/UTP, 23 AWG
Design with excellent transmission properties. Ideally suited to interconnect telecom and data system in structured data networks. The cable is polyolefin insulated, pair twisted and jacketed with a halogen-free compound. Intended for indoor use.
  • Halogen-free design
  • Unscreened
  • Conductor  23 AWG
  • UL listed CM


TEL 301 8020 ECEFQBU/100, Cat 7 S/FTP, 23 AWG
Designed for future proof installations in data and multimedia networks. The cable is polyolefin insulated, pair twisted and screened by an aluminum foil. Overall screened by a tinned copper braid and jacketed with a halogen-free compound. Intended for indoor use.
  • Halogen-free design
  • Screened by AL-foil and braid
  • Conductor 23 AWG
  • UL listed CMR


TEL 426  ELAFQBU/100,  Modified Cat 5 SF/UTP, 26 AWG
Modified SF/UTP cat 5, 26 AWG version, designed for interconnect data bus links within telecom applications. Robust design with solid PE insulation, pair twisted, screened by an AL-foil and braid jacketed with a halogen-free, flame-retardant compound.
  • Halogen-free design
  • Screened by AL-foil and braid
  • Conductor 0.4 mm, 26 AWG
  • UL listed CMR
  • No. of pairs 4-12


TEL 301 6009  ECAFQBU/100, Modified Cat 5e SF/UTP, 26 AWG
Modified SF/UTP cat 5e, 26 AWG cable designed for installation in structured networks and intermediate links interconnecting data and telecom system. The cable is polyolefin foamskin insulated, pair twisted and screened by an aluminum foil and braid. Overall a jacket of halogen-free compound is applied. Intended for indoor use.
  • Halogen-free design
  • Screened by AL-foil and braid
  • Conductor 0.4 mm, 26 AWG
  • 1000 base-T limited length 60 m
  • UL listed CMR


TEL 301 6005 ELAFI/100, Modified Cat 5e SF/UTP, 26 AWG
Modified SF/UTP cat 5e, 26 AWG cable designed for interconnecting data bus links within indoor and outdoor telecom applications. Robust design with solid PE insulation, pair twisted, screened by an AL-foil and braid jacketed with a halogen-free, flame-retardant, weather-proof TPE-U compound.
  • Halogen-free design
  • Indoor and outdoor applications
  • Conductor 0.4 mm, 26 AWG
  • 1000 base-T limited length 60 m
  • UL listed VW-1


TEL 301 5002 ELQXBU/100, Modified U/UTP Cat 5, 30 AWG
Designed for interconnection of transmission systems requiring small cable dimensions. The cable is halogen free with polyolefin insulation, pair twisted and jacketed with a halogen-free, flame-retardant compound. Intended for indoor use.
  • Halogen-free design
  • Cable sizes 4-24 pair
  • Unscreened
  • 1000 base-T limited length 35 m
  • Conductor 0.25 mm, 30 AWG
  • UL listed CM


TEL 301 6007 EMAFQBU/100, Modified Cat 5 SF/UTP, 30 AWG
Designed for interconnection of transmission systems requiring small cable dimensions. The cable is halogen free with polyolefin insulation, pair twisted, screened by an aluminum foil and braid and jacketed with a halogen-free, flame-retardant compound. Intended for indoor use.
  • Halogen-free design
  • Screened by AL-foil and braid
  • Cable sizes 4-24 pair
  • 1000 base-T limited length 30 m
  • Conductor 0.25 mm, 30 AWG
  • UL listed CM


TEL 301 6029 EMAFQBU/100, Modified Cat 5 SF/UTP, 28 AWG
Designed for interconnection of transmission systems requiring small cable dimensions. The cable is halogen free with polyolefin insulation, pair twisted, screened by an aluminum foil and braid and jacketed with a halogen-free, flame-retardant compound. Intended for indoor use.
  • Halogen-free design
  • Screened by AL-foil and braid
  • Cable sizes  4, 2x4 pair
  • 1000 base-T limited length 40 m
  • Conductor 0.32 mm, 28 AWG
  • UL listed CM


TEL 301 5205 ELQXBU/100, Modified Cat 5 U/UTP, 26 AWG
UTP cable designed for installation in Telecom networks interconnecting data and telecom system with VDSL2 transmission. The cable is polyolefin insulated, pair twisted and jacketed with a halogen-free compound. Intended for indoor use.
  • Halogen-free design
  • Unscreened
  • Cable size  12 pair
  • Conductor 0.4 mm, 26 AWG
  • UL listed CM


TEL 301 8001 ELEFQBU/100, Modified S/FTP cat 7, 30 AWG
Combines the properties of a compact design and high level of signal integrity for multi pair cables. The silver plated conductors are insulated with PE, pair twisted and pair screened covered by a common braid and a halogen-free, flame-retardant compound.
  • Halogen-free design
  • Pair screened by Al- foil
  • No. of pairs 4-24
  • Impedance 100 ohm
  • Conductor 0.25 mm, 30 AWG
  • UL listed CMR