Data, Signal and Alarm cables
Data cables for Structured Networks

TFL 301 5010 FMQXB/100, Cat5e U/UTP, Patch
Flexible U/UTP patch cable for interconnecting data and telecom equipment. Polypropylene insulated stranded wire, pair twisted and jacketed with a halogen-free compound. Intended for indoor use.
- Halogen-free design
- Screened by AL-foil and braid
- Conductor, tin plated stranded wire, 26 AWG
- UL listed CMR

TEL 301 6010
ECAFQBU/100, Cat5e SF/UTP Designed for interconnecting data bus links within telecom and datacom applications. Foamed PE insulation, pair twisted, screened by an AL-foil and braid jacketed with a halogen-free, flame-retardant compound. Extending EMC properties of standard CAT5e cable.
- Halogen-free design
- Screened by AL-foil and braid
- Conductor 0.5 mm, 24 AWG
- UL listed CMR

TFL 301 6010
FLAFQBU/100, Cat5e SF/UTP, Patch Designed for interconnecting data bus patch links with in telecom and datacom applications. Robust design with solid PE insulation on a stranded tinned cu wire, pair twisted, screened by an AL-foil and braid jacketed with a halogen-free, flame-retardant compound.
- Halogen-free design
- Screened by AL-foil and braid
- Conductor 0.14 mm2, 26 AWG
- UL listed CMR

TEL 301 8010
ECEFQBU/100, Cat6 S/FTP Design with excellent transmission properties. Ideally suited to interconnect telecom and data system in structured data networks. The cable is polyolefin insulated, pair twisted and screened by an aluminum foil. Overall screened by a tinned copper braid and jacketed with a halogen-free compound. Intended for indoor use.
- Halogen-free design
- Screened by AL-foil and braid
- Cconductor 23 AWG
- UL listed CMR

TEL 301 8011
ECEFQBU/100, Cat6 S/FTP
Optimized design downsized to 26 AWG offering reduced dimension with excellent transmission properties. Ideally suited to interconnect telecom and data system. The cable is polyolefin insulated, pair twisted and screened by an aluminum foil. Overall screened by a tinned copper braid and jacketed with a halogen-free compound. Intended for indoor use.
- Halogen-free design
- Screened by AL-foil and braid
- Conductor 26 AWG
- UL listed CMR

TEL 301 8018
ECEFL/100, Cat6 S/FTP, Outdoor
S/FTP Cat 6 design with excellent transmission properties. Ideally suited to interconnect telecom and data system in outdoor structured data networks. The cable is polyolefin insulated, pair twisted and screened by an aluminum foil. Overall screened by a tinned copper braid and jacketed with Polyethylene.
- Weather-proof for outdoor use
- Halogen-free design
- Screened by AL-foil and braid
- Conductor 23 AWG
- UL listed CMR

TEL 301 5020
EMQXBU/100, Cat6 U/UTP Design with excellent transmission properties. Ideally suited to interconnect telecom and data system in structured data networks. The cable is polyolefin insulated, pair twisted and jacketed with a halogen-free compound. Intended for indoor use.
- Halogen-free design
- Unscreened
- Conductor 23 AWG
- UL listed CM

TEL 301 8020
ECEFQBU/100, Cat7 S/FTP
Design for future proof installations in data and multimedia networks. The cable is polyolefin insulated, pair twisted and screened by an aluminum foil. Overall screened by a tinned copper braid and jacketed with a halogen-free compound. Intended for indoor use.
- Halogen-free design
- Screened by AL-foil and braid
- Conductor 23 AWG
- UL listed CMR
Signal and Alarm Cables for Premises Network

TEL 310 201 ELQRB
Intended for signal and alarm systems for in and outdoor applications. Polyethylene insulated and
jacketed with flame-retardant halogen-free compound.

TEL 310 0087 ELQYB 1.0
Intended for fire alarm systems for in and outdoor applications. Polyethylene insulated and jacketed with flame retardant halogenfree compound.

RKKR
Flexible cable for indoor signal applications PVC insulated and jacketed.

PFSK
Intended for signal systems for in and outdoor applications. PVC insulated and jacketed Sceened by tinned copperbraid.

PTS
Signal and alarm cable for indoor applications. PVC insulated and jacketed pair tvisted and screened by AL-foil.