Skip navigation

Security Bulletin – Ericsson Packet Core Controller (PCC), August 2024

Summary:

Ericsson has released an update for Packet Core Controller to address security issues that may lead to a restart of the system potentially causing service degradation.

Vulnerability description:

This section summarizes the vulnerability issue and potential impact that this security update addresses.

CVE-2024-25009 - Ericsson Packet Core Controller (PCC) contains a vulnerability in Access and Mobility Management Function (AMF) where improper input validation can lead to denial of service which may result in service degradation.

CVSS Base Score: 6.5
Severity: Medium
CVSS Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Weakness Type: CWE-20 Improper Input Validation

Security update:

The following table lists the Ericsson products affected, versions affected, and the updated version that includes this security update. To protect your system, download and install the updated version.

CVE addressed Product name Affected versions Updated versions
CVE-2024-25009   Packet Core Controller (PCC)   All versions prior to PCC 1.33  

PCC 1.33
PCC 1.32 CP10

Acknowledgement:

Ericsson thanks following people for reporting this issue to us:

  • Radu Balaci and Meghna Patel of Bell Mobility (Canada)
  • Benoit Michau of P1 Security (France)

Additional information:

  • Ericsson severity assessment of a vulnerability is based on an average of risk across a diverse set of installed systems and may not represent the true risk to your organization. We recommend evaluating the risk to your specific configuration.
  • If you have any questions regarding this bulletin, please reach out to your local Ericsson support representative.
  • Learn more about the vulnerability management process followed by the Ericsson Product Security Incident Response Team (PSIRT), see Ericsson PSIRT page.

Revision history:

Revision Date Description
1.0 August 20, 2024 Initial Release

© Ericsson AB 2024. All rights reserved. No part of this message may be reproduced in any form without the written permission of the copyright owner. The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this message. For questions, please contact Ericsson Local Support or connect with us on the Omni Network Channel section of My Ericsson. Visit us at Support User Preferences to unsubscribe.